Comparison between volar plating and external fixation augmented by Kirshner wires in comminuted distal radial fractures

Автор: Attia Usama F., El-soufy Mohamed A., El-hewala Tarek A.E., Abdelrazek Mohamed A.

Журнал: Гений ортопедии @geniy-ortopedii

Рубрика: Оригинальные статьи

Статья в выпуске: 3 т.28, 2022 года.

Бесплатный доступ

Background Volar locking plate (VLP) has gained the most popularity in the treatment of distal radius fractures due to its superior biomechanical property. In contrast, external fixation (EF) is not so extensively used. The aim of this study was to find what procedure is better in the management and achieves favorable outcomes in patients with comminuted distal radial fractures. Patient and methods This study included 30 patients with distal radial fractures AO types A3, C2, C3 in which 15 ubjects were managed with open reduction and internal fixation by volar plate, and another 15 were managed with external fixation augmented by K-wires. The minimum duration of follow-up in our study was six months. Results Patients treated with external fixation augmented by K-wires had grip strength range 15-27, patients treated with volar plating had grip strength range 8-27. There was no significant statistical difference between 2 groups regarding extension. In Group A Mann-Whitney test revealed that Gartland-Werely score had negative correlation with affected hand. In Group B the correlation was positive with AO/OTA classification only and negative with affected hand and ulnar styloid fracture but also not statistically significant between Quick-DASH score with affected hand, AO/OTA classification and ulnar styloid fracture. Conclusion Both volar plating and external fixation augmented by K-wires are treatment choices for distal radius fractures. Whereas external fixation maintains a significant role in the treatment of distal radius fractures, ORIF with locked volar plating has changed the way many surgeons treat certain types of distal radius fractures.

Еще

Volar plating, external fixation, radial fractures, dash score

Короткий адрес: https://sciup.org/142235328

IDR: 142235328   |   DOI: 10.18019/1028-4427-2022-28-3-322-327

Список литературы Comparison between volar plating and external fixation augmented by Kirshner wires in comminuted distal radial fractures

  • Cooney W.P. 3rd, Linscheid R.L., Dobyns J.H. External pin fixation for unstable Colles' fractures // J. Bone Joint Surg. Am. 1979. Vol. 61, No 6A. P. 840-845.
  • A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older / R. Arora, M. Lutz, C. Deml, D. Krappinger, L. Haug, M. Gabl // J. Bone Joint Surg. Am. 2011. Vol. 93, No 23. P. 2146-2153. DOI: 10.2106/JBJS.J.01597.
  • Aspects of Current Management of Distal Radius Fractures in the Elderly Individuals / R. Arora, M. Gabl, S. Erhart, G. Schmidle, C. Dallapozza, M. Lutz // Geriatr. Orthop. Surg. Rehabil. 2011. Vol. 2, No 5-6. P. 187-194. DOI: 10.1177/2151458511426874.
  • Randomized comparison of volar locking plates and intramedullary nails for unstable distal radius fractures / J.F. Plate, D.L. Gaffney, C.L. Emory, S. Mannava, B.P. Smith, L.A. Koman, E.R. Wiesler, Z. Li // J. Hand Surg. Am. 2015. Vol. 40, No 6. P. 1095- 1101. DOI: 10.1016/j.jhsa.2015.02.014.
  • Open reduction and internal fixation with conventional plate via L-shaped lateral approach versus internal fixation with percutaneous plate via a sinus tarsi approach for calcaneal fractures - a randomized controlled trial / S. Xia, Y. Lu, H. Wang, Z. Wu, Z. Wang // Int. J. Surg. 2014. Vol. 12, No 5. P. 475-480. DOI: 10.1016/j.ijsu.2014.03.001.
  • Prospective study of distal radius fractures treated with a volar locking plate system / D. Osada, S. Kamei, K. Masuzaki, M. Takai, M. Kameda, K. Tamai // J. Hand Surg. Am. 2008. Vol. 33, No 5. P. 691-700. DOI: 10.1016/j.jhsa.2008.01.024.
  • Malpractice in distal radius fracture management: an analysis of closed claims / P.H. de Noble, A.C. Marshall, O.A. Barron, L.W. Catalano 3rd, S.Z. Glickel // J. Hand Surg. Am. 2014. Vol. 39, No 8. P. 1480-1488. DOI: 10.1016/j.jhsa.2014.02.019.
  • Chung K.C., Shauver M.J., Birkmeyer J.D. Trends in the United States in the treatment of distal radial fractures in the elderly // J. Bone Joint Surg. Am. 2009. Vol. 91, No 8. P. 1868-1873. DOI: 10.2106/JBJS.H.01297.
  • Complications following volar locking plate fixation for distal radial fractures: a systematic review / A. Bentohami, K. de Burlet, N. de Korte, M.P. van den Bekerom, J.C. Goslings, N.W. Schep // J. Hand Surg. Eur. Vol. 2014. Vol. 39, No 7. P. 745-754. DOI: .10.1177/1753193413511936.
  • Dorsal or Volar Plate Fixation of the Distal Radius: Does the Complication Rate Help Us to Choose? / D.J. Disseldorp, P.F. Hannemann, M. Poeze, P.R. Brink // J. Wrist Surg. 2016.Vol. 5, No 3. P. 202-210. DOI: 10.1055/s-0036-1571842
  • Indirect reduction and percutaneous fixation versus open reduction and internal fixation for displaced intra-articular fractures of the distal radius: a randomised, controlled trial / H.J. Kreder, D.P. Hanel, J. Agel, M. McKee, E.H. Schemitsch, T.E. Trumble, D. Stephen // J. Bone Joint Surg. Br. 2005. Vol. 87, No 6. P. 829-836. DOI: 10.1302/0301-620X.87B6.15539.
  • Reynolds P.R., Beredjiklian P.K. External fixation of distal radius fractures: do benefits outweigh complications? // Curr. Opin. Orthop. 2001. Vol. 12, No 4. P. 286-289. DOI: 10.1097/00001433-200108000-00004.
  • Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials / Q. Fu, L. Zhu, P. Yang, A. Chen // Indian J .Orthop. 2018. Vol. 52, No 6. P. 602-610. DOI: 10.4103/ortho.IJOrtho_601_16.
  • Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a meta-analysis / M.M. Walenkamp, A. Bentohami, M.S. Beerekamp, R.W. Peters, R. van der Heiden, J.C. Goslings, N.W. Schep // Strategies Trauma Limb Reconstr. 2013. Vol. 8, No 2. P. 67-75. DOI: 10.1007/s11751-013-0169-4.
  • Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study / S. Rein, H. Schikore, W. Schneiders, M. Amlang, H. Zwipp // J. Hand Surg. Am. 2007. Vol. 32, No 7. P. 954-961. DOI: 10.1016/j.jhsa.2007.05.008.
  • Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures / Y.C. Chou, A.C. Chen, C.Y. Chen, Y.H. Hsu, C.C. Wu // J. Hand Surg. Am. 2011. Vol. 36, No 6. P. 974-981. DOI: 10.1016/j.jhsa.2011.02.024.
  • Earp B.E., Foster B., Blazar P.E. The use of a single volar locking plate for AO C3-type distal radius fractures // Hand (N Y). 2015. Vol. 10, No 4. P. 649-653. DOI: 10.1007/s11552-015-9757-8.
  • [Combination of volar buttress plate with external fixatior for the distal radial fractures of type C3 caused by high-energy injuries] / Y.S. Deng, Q.L. Zhang, Q.G. Wang, F. Ji, X.B. Cai, H. Tang, J.H. Wu, F. Wang, X.R. Tang, Y. Xie, Z.M. Guan, C.W. Yang, Q. Wang // Zhongguo Gu Shang. 2009. Vol. 22, No 7. P. 543-546. (in Chinese)
  • Volar locking compression plate combined with external fixation for treatment of AO type C3 distal radius fractures / J. Cao, G. Shen, J. Lu, et al. // Clin. Med. China. 2013. Vol. 29. P. 118-120.
  • Gliatis J.D., Plessas S.J., Davis T.R. Outcome of distal radial fractures in young adults // Hand Surg. Br. 2000. Vol. 25, No 6. P. 535-543. DOI: 10.1054/ jhsb.2000.0373.
  • Volar locking plate versus K-wire-supported external fixation in the treatment of AO/ASIF type C distal radius fractures: a comparison of functional and radiological outcomes / A. Duramaz, M.G. Bilgili, E. Karaali, B. Bayram, N. Ziroglu, C. Kural // Ulus. Travma Acil. Cerrahi Derg. 2018. Vol. 4, No 3. P. 255-262. DOI: 10.5505/tjtes.2017.35837.
  • Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study / X. Yu, Y. Yu, X. Shao, Y. Bai, T. Zhou // J. Orthop. Surg. Res. 2019. Vol. 14, No 1. P. 271. DOI: 10.1186/s13018-019-1309-4.
  • Rizzo M., Katt B.A., Carothers J.T. Comparison of locked volar plating versus pinning and external fixation in the treatment of unstable intraarticular distal radius fractures // Hand (N Y). 2008. Vol. 3, No 2. P. 111-117. DOI: 10.1007/s11552-007-9080-0.
  • Prospective randomised study of intra-articular fractures of the distal radius: comparison between external fixation and plate fixation / G.G. Xu, S.P. Chan, M.E. Puhaindran, W.Y. Chew // Ann. Acad. Med. Singap. 2009. Vol. 38, No 7. P. 600-606.
  • Mid-term functional outcome after the internal fixation of distal radius fractures / J. Phadnis, A. Trompeter, K. Gallagher, L. Bradshaw, D.S. Elliott, K.J. Newman // J. Orthop. Surg. Res. 2012. Vol. 7. P. 4. DOI: 10.1186/1749-799X-7-4.
  • Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius / M.J. Richard, D.A. Wartinbee, J. Riboh, M. Miller, F.J. Leversedge, D.S. Ruch // J. Hand Surg. Am. 2011. Vol. 36, No 10. P. 1614-1620. DOI: 10.1016/j.jhsa.2011.06.030.
  • Volar locking plates versus external fixation and adjuvant pin fixation in unstable distal radius fractures: a randomized, controlled study / J.H. Williksen, F. Frihagen, J.C. Hellund, H.D. Kvernmo, T. Husby. // J. Hand Surg. Am. 2013. Vol. 38, No 8. P. 1469-1476. DOI: 10.1016/j.jhsa.2013.04.039.
  • Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: a randomized study of 50 patients / A. Abramo, P. Kopylov, M. Geijer, M. Tagil // Acta Orthop. 2009. Vol. 80, No 4. P. 478-485. DOI: 10.3109/17453670903171875.
  • A randomized prospective study on the treatment of intra-articular distal radius fractures: open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation, and external fixation / R. Grewal, B. Perey, M. Wilmink, K. Stothers// J. Hand Surg. Am. 2005. Vol. 30, No 4. P. 764-772. DOI: 10.1016/j.jhsa.2005.04.019.
  • Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: a randomized controlled trial / A. Karantana, N.D. Downing, D.P. Forward, M. Hatton, A.M. Taylor, B.E. Scammell, C.G. Moran, T.R. Davis // J. Bone Joint Surg. Am. 2013. Vol. 95, No 19. P. 1737-1744. DOI: 10.2106/JBJS.L.00232.
  • Volar Locking Plate or External Fixation with Optional Addition of K-Wires for Dorsally Displaced Distal Radius Fractures: A Randomized Controlled Study / C. Mellstrand Navarro, L. Ahrengart, H. Tornqvist, S. Ponzer // J. Orthop. Trauma. 2016. Vol. 30, No 4. P. 217-224. DOI: 10.1097/ B0T.0000000000000519.
Еще
Статья научная